Factory direct from Qingdao · OEM & ODM welcome

L LUNLUXDecorative Lighting

Menu

All productsSand Art Lamps (4)Rechargeable Table Lamps (40)Luxury Chandeliers (2)Ceiling Lights (9)Custom Linear LED (4)Portable Handle Lamps (6)Night Lights (10)Ambient Lights (15)Fabric Shade Lamps (7)Wall Lights (2)Light Boards (1)HomeAboutOEM / ODMFAQContactWhatsApp us

Custom linear LED: what to send us

A custom linear quote is only as good as the drawing behind it. These are the seven pieces of information that let a factory price a non-standard run without three rounds of email.

1. The run, measured — not estimated

Start with the total run length in millimetres, measured along the mounting surface rather than across the room. If the run is broken by columns, give each segment separately with the gaps marked. A single 'about eight metres' will produce a quote that changes once someone measures properly.

If you have a reflected ceiling plan or a DWG, send it. A photograph of the ceiling with a tape measure in frame is a surprisingly good second option — it shows obstructions and heights that a plan often misses.

2. Mounting type: surface, suspended or trunking

Surface mounting suits ceilings where nothing should hang below the plane. Suspended profiles hang on steel wires and suit open ceilings, with the height set on site. Trunking mounting clips to a continuous rail and is used where the run has to continue past obstacles in commercial or industrial spaces.

Tell us which one, because the profile and the accessory set differ. If the ceiling is exposed concrete or a services void, say so: it changes the suspension calculation and sometimes the profile width.

3. Profile width and the reason for it

Standard widths are 50, 70, 100, 150, 180 and 280 mm. The width is usually set by the light level required and the ceiling height rather than by taste: a narrow profile in a tall space reads as a line, a wide profile in a low space reads as a panel. Tell us the ceiling height and the intended illuminance if you have a lighting designer's specification.

4. Output, colour temperature and dimming

Colour temperature is specified per project, typically 3000 K for hospitality, 4000 K for offices and retail, 6000 K for industrial areas. Mixed CCTs in one building need to be stated run by run.

Dimming is the item most often left until the end, and it is the one that causes site problems. If the building already has a control system, tell us the protocol — 0–10 V, DALI or triac — and whether the driver sits in the profile or remotely. A run that cannot be dimmed to match the rest of the floor will be rejected on site, not in the quotation.

5. Corners, radius sections and tap-off points

Straight runs are the easy part. Where the run turns a corner, the corner piece is either a mitred joint or a radius section, and each is priced separately. Mark corners on the drawing and note the radius if there is one.

Tap-off points are where the power enters the run and where it continues. Mark them on the drawing. If the electrical contractor has not fixed them yet, tell us and we will suggest positions based on the run length and the driver rating.

6. Finish and environment

Powder coat in black, white or silver covers most interiors. Anodised finishes suit visible architectural work; plated finishes suit hospitality interiors where the fixture is seen up close. If the space is humid, coastal or semi-outdoor, say so — it changes the sealing and the IP rating, and it is much cheaper to decide before extrusion than after installation.

7. Quantities and the commercial frame

Give the total metres and the number of separate lengths, because cutting waste is real: a 2.4 m run from 3 m stock leaves offcuts that have to be paid for. Tell us whether this is a one-off project or the first of several floors, and whether the profile will be private-labelled.

With those seven items — measured run, mounting, width, output and dimming, corners, finish and quantities — a linear quote can be issued without a site visit. Without them, every answer is an assumption, and assumptions on linear lighting usually surface on installation day.

Sourcing this range? Send the models and quantities and we will quote with carton data and lead time.

Start an inquiry